Ir arriba
Información del artículo

Optimal operation of energy hubs including parking lots for hydrogen vehicles and responsive demands

M. Nasir, A.R. Jordehi, S.A. Alavi Matin, V. Sohrabi Tabar, M. Tostado-Véliz, S.A. Mansouri

Journal of Energy Storage Vol. 50, pp. 104630-1 - 104630-19

Resumen:

Energy hubs (EHs) are units that enable the simultaneous supply of different types of energy demands by converting energy carriers, and using energy storage systems. Energy storage systems can significantly help maintain the balance between energy production and energy demand, while enabling the use of renewable energy resources, and improve the flexibility of energy hubs through the efficient management of energy supply. In this study, a stochastic model is designed for unit commitment (UC) in Energy hubs, which include hydrogen vehicle (HV) parking lot, electric heat pump (EHP), absorption chiller (AC), photovoltaic (PV) module, boiler, hydrogen electrolyzer (HE) and electric, thermal, cooling and hydrogen storage systems. Here, natural gas (NG) and electricity are the input of the EH and are used to supply electric, hydrogen, heat, cooling and NG demands. In this work, uncertainties of demands, the initial power of hydrogen vehicle tanks and PV power are modeled, and the impact of storage systems, parking lot and demand response on EH operation are also investigated. The proposed mixed integer linear programming (MILP) model is solved for unit commitment in EH using the CPLEX solver in the GAMS software. The results show that the EH operation cost is reduced by 27.58% in the presence of demand response, energy storage systems by 12.68%, and hydrogen vehicles by 2.9%. In addition, according to the results, it can be found that the cooling storage system by 6.19% has the significant impact on reducing EH operation costs compared to electrical, hydrogen and thermal storage systems, while electric demand response by 15.89% reduction in operation costs is more effective than others. Moreover, the impact of different contingencies on the EH operation is evaluated. The results indicate that the hydrogen demand is fully supplied despite the exit of the power grid. This is particularly due to the presence of hydrogen vehicles (HV tanks) in the model. Also, simulations show that the outage of the power grid leads to 1288.64 kW of energy not served.


Palabras Clave: Energy hubs; Optimization; Unit commitment; Hydrogen vehicles; Uncertainty


Índice de impacto JCR y cuartil WoS: 9,400 - Q1 (2022); 8,900 - Q1 (2023)

Referencia DOI: DOI icon https://doi.org/10.1016/j.est.2022.104630

Publicado en papel: Junio 2022.

Publicado on-line: Abril 2022.



Cita:
M. Nasir, A.R. Jordehi, S.A. Alavi Matin, V. Sohrabi Tabar, M. Tostado-Véliz, S.A. Mansouri, Optimal operation of energy hubs including parking lots for hydrogen vehicles and responsive demands. Journal of Energy Storage. Vol. 50, pp. 104630-1 - 104630-19, Junio 2022. [Online: Abril 2022]


pdf Previsualizar
pdf Solicitar el artículo completo a los autores